Evaluation of Sulfuric Acid Effect on Torsional Strength of Steel Used in Concrete Reinforcement in Sanitation Structures
Keywords:
Concrete Cover, Microbiologically Induced Deterioration, Sanitation Structures, Strength Reduction, Sulfuric acid, Torsional StrengthAbstract
Most sanitation structures in the world are constructed using concrete which is reinforced by the steel, this type of concrete is called Reinforced Cement Concrete (RCC). The RCC structure is believed to be relatively resistant to corrosion which the sanitation structures are prone to due to the aggressive environment in which they are subjected to. This belief has been compromised since the reinforced concrete used in the sanitation structures such as the concrete sewer pipes has become susceptible to Microbiologically Induced Deterioration (MID). This MID leads to degradation and compromised strength and service life of the RCC. In the reinforced concrete structure, the backbone of this structure is the reinforcing steel which when its strength is compromised by the MID, the whole structure is compromised. The present research therefore aimed at evaluating the effects of sulfuric acid, resulting from the MID process, on the torsional strength of steel metal used for reinforcing concrete in sanitation structures. Reinforced concrete specimens were developed using different types of cement and different concrete cover. The three different types of cement were, Ordinary Portland Cement (OPC), Portland Pozzolana Cement (PPC) and Limestone Calcined Clay Cement (LC3), while concrete covers of 15mm and 25mm were applied. They were then subjected to aggressive environment (a sample of sewage) suitable for corrosion just like in their actual operational environment. To determine the effects of sulfuric on the torsional strength of the steel, metal was tested using Torsion Machine (TM). The torsional strength before and after being subjected to aggressive environment was determined. The testing of the specimens was done at an interval of 14 days for a period of three (3) months. According to the results, for a concrete cover of 25mm, LC3 showed minimum percentage reduction in strength compared to PPC and OPC. It had the lowest percentage reduction in strength after 84 days which was 5.25%, OPC 7.20%, and PPC 7.24%. In conclusion, LC3 showed good resistance to the effects of sulfuric acid compared to PPC and OPC. In terms of concrete cover, 25mm showed good resistance to the effects compared to 15mm concrete cover.
Downloads
Published
How to Cite
Issue
Section
License
Copyright (c) 2025 Meru Universty of Science and Technology International Conference (MUSTIC)

This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.